  2. Anwendungen
  3. Molten sulphur accurate level measurement

Molten sulphur accurate level measurement

Not every level measurement application is straightforward. In some instances, the nature of the substance being measured creates a hostile measurement atmosphere requiring creative solutions. Without reliable instruments in these environments, the level measurement readings can be inaccurate and cause significant problems.

A gas production company required an accurate level measurement in a  molten sulfur pit. Previously, the company used a bubble system, but it requires periodic maintenance and recalibration to keep it operational. Obtaining an accurate level measurement is difficult in this application due to both the low dielectric of the process medium and dry sulfur buildup. In addition, the relatively high temperature (150°C) and the corrosive properties of the molten sulfur increased the demands for service and maintenance.

Solution

Eclipse guided wave radars for molten sulfur

The Eclipse® 706 - guided wave radar transmitter - provides accurate and reliable level measurements in difficult process conditions. Comparing to other technologies, it requires less maintenance and does not need calibration. To ensure the maximum accuracy and reliability the transmitter was delivered with 7YF single-rod probe. Before the Eclipse was accepted as the molten sulfur pit level control device, it was tested and monitored for two weeks. Plant operators, using the manual hand-dipped method, inspected measurement made by the transmitter. After testing period, the performance of the Eclipse was verified and its application was endorsed. The single-rod probe performed well despite the problems that can be caused by sulfur buildup or coating. A  strong pulse was still detected from the liquid surface despite the buildup. Reliable level measurement of molten sulfur in a pit is difficult to obtain. The Eclipse proved to be an excellent solution for process level control that was not adversely affected by high temperature, probe build-up, or the corrosive properties of the media measured.

Features

  • reliable measurement without
  • no need for complicated maintenance
  • probe does not require calibration and re-calibration
  • high temperature resistance
  • integral or remote electronics
  • ATEX approval

Benefits

  • accurate and reliable level measurement
  • no maintenance and cleaning troubles
  • process optimization
  • elimination of shutdown costs
  • real-time, continuous vizualization

Rafał Nowicki

Rafał Nowicki

Marketing

+48 607 701 119

E-mail
  1. Verwendete Produkte
    1. Hochleistungs-Füllstandmessumformer

      Eclipse® 706 Hochleistungs-Füllstandmessumformer

      Neue Generation des geführten Radars (GWR) mit erhöhter Signalstärke

      Mehr

Kontaktdaten

MERCON GmbH

Im Technologiepark 1
15236 Frankfurt (Oder)

Telefon:
0335 557 1511
E-mail:
Weitere Informationen
  1. Produkte
  2. Service
  3. Anwendungen
  4. Aktuelles
  5. Über uns
  6. Downloads
  7. Karriere
  8. Kontakt

Datenschutzhinweise
© 2016-2020 MERCON

Produkt finden

Design by Tonik

X Unsere Website verwendet Cookies. Wenn Sie damit nicht einverstanden sind, ändern Sie bitte Ihre Cookie-Einstellungen.